Related Experiment Video
Updated: May 26, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Impression techniques for multiple implants: a photoelastic analysis. Part II: comparison of four acrylic resins
Itamar Lopes-Júnior1, Barbara de Lima Lucas, Henner Alberto Gomide
1Faculty of Dentistry, Federal University of Uberlandia, Uberlandia, Minas Gerais, Brazil.
Abstract:
Four commercial brands of chemically activated acrylic resin were compared through photoelastic analysis. Photoelastic resin blocks were made with 2 implants placed parallel to each other and 2 square transfer copings splinted. Both transfers were splinted with chemically activated acrylic resin: Dencrilay, Duralay I, Duralay II, and GC. Data were analyzed by 2-way analysis of variance and Tukey test (P < .05). Statistically significant differences were found among the 3 brands of chemically activated acrylic resin. Dencrilay showed greater dimensional alteration. Duralay I and GC are recommended for the transfer of the position of the multi-implants.