Related Experiment Video
Updated: May 26, 2026

Using the Endoscope for Endobronchial Ultrasound in the Esophagus
Published on: November 21, 2023
Synchronous endoscopy and sonotubometry of the eustachian tube: a pilot study
Ophir Handzel1, Dennis Poe, Robert J Marchbanks
1Department of Otolaryngology/Head and Neck, Oro-Maxillary Surgery, Tel-Aviv Sourasky Medical Center, Tel-Aviv University, Tel-Aviv, Israel.
Objective:
To describe for the first time a method of recording of Eustachian tube (ET) function by simultaneous and synchronous endoscopy and sonotubometry and explore its advantages compared with the performance of these tests independently.
Study Design:
Observational study.
Setting:
Academic tertiary medical center.
Patients:
Eighteen healthy subjects.
Intervention:
Endoscopic nasopharyngoscopy with simultaneous, synchronous sonotubometry. Each subject performed three maneuvers: pronouncing the constant "k", swallowing and yawning.
Main Outcome Measures:
The number of ET opening as a fraction of all efforts to open the tube, the duration of each opening and the sound intensity recorded by sonotubometry.
Results:
Six (35.3%) of 17 subjects used for data analysis did not open their ET during swallowing. Excluding nonopeners, the ET opened in 3 of 4 of the swallows. The average duration of opening of the ET during swallowing was 0.44 seconds. The ET does not open every time the endoscopic view notes dilation. A negative sound pressure wave was recorded in a number of instances, immediately preceding a swallow-related opening. Contraction of the tensor veli palatini muscle was essential for ET opening.
Conclusion:
Simultaneous synchronous endoscopy and sonotubometry may improve the accuracy of either performed separately as an ET function measurement tool. Sonotubometry may prevent a false-positive endoscopy (ET viewed as open but no functional patency achieved). Endoscopy can lower the threshold considered as positive for sonotubometry. A negative pressure wave recorded by sonotubometry may reflect the ET role of clearing the middle ear of secretions toward the nasopharynx. This novel measurement technique provided additional evidence that the tensor veli palatini muscle provides the final opening action of the ET.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Suctioning the Nasopharyngeal Airway
Equipment Required
