Related Experiment Video
Updated: May 26, 2026

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Assessment of sensing fire fighters uniforms for physiological parameter measurement in harsh environment
Davide Curone1, Emanuele Lindo Secco, Laura Caldani
1European Centre for Training and Research in Earthquake Engineering, Pavia, Italy. davide.curone@eucentre.it
Abstract:
In the last few years, much effort has been devoted to the development of wearable sensing systems able to monitor physiological, behavioral, and environmental parameters. Less has been done on the accurate testing and assessment of this instrumentation, especially when considering devices thought to be used in harsh environments by subjects or operators performing intense physical activities. This paper presents methodology and results of the evaluation of wearable physiological sensors under these conditions. The methodology has been applied to a specific textile-based prototype, aimed at the real-time monitoring of rescuers in emergency contexts, which has been developed within a European funded project called ProeTEX. Wearable sensor measurements have been compared with the ones of suitable gold standards through Bland-Altman statistical analysis; tests were realized in controlled environments simulating typical intervention conditions, with temperatures ranging from 20 °C to 45 °C and subjects performing mild to very intense activities. This evaluation methodology demonstrated to be effective for the definition of the limits of use of wearable sensors. Furthermore, the ProeTEX prototype demonstrated to be reliable, since it produced negligible errors when used for up to 1 h in normal environmental temperature (20 °C and 35 °C) and up to 30 min in harsher environment (45 °C).
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...