Related Experiment Video
Updated: May 26, 2026

Transport Properties of Ibuprofen Encapsulated in Cyclodextrin Nanosponge Hydrogels: A Proton HR-MAS NMR Spectroscopy Study
Published on: August 15, 2016
[Evaluation of the retention properties of two cyclodextrin stationary phases with different spacers]
Yanyan Zhao1, Zhimou Guo, Xingya Xue
1Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
Abstract:
A set of 14 model compounds were selected to evaluate the retention properties of two silica-based cyclodextrin (CD) bonded stationary phases with different spacers (Click Alkyl-CD and Click OEG-CD) under reversed-phase liquid chromatographic (RPLC) mode. The gradient calculation method and CSASS software developed in our group were applied to obtain the retention parameters of the 14 solutes on the two CD bonded stationary phases under 3 gradient conditions. The effect of acetonitrile content in the mobile phase on the retention of both CD stationary phases was studied. It was found that the retention of non-polar and medium polar compounds on the both stationary phases was based on RPLC mode, while the retention of some compounds (such as indazole) on Click OEG-CD was influenced by several kinds of interactions and was not based on RPLC mode. The hydrophobic property of the two CD stationary phases in RPLC mode was studied. High correlation value (R = 0.7) between the retention parameter of Click Alkyl-CD and n-octanol-water partition coefficients of the solutes indicated the high hydrophobicity of Click Alkyl-CD. Nevertheless, the low correlation value (R < 0.3) between the retention parameter of Click OEG-CD and n-octanol-water partition coefficients indicated the presence of influence of other interactions in addition to hydrophobic interaction on the retention in RPLC mode.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
07:32Preparation and Characterization of Individual and Multi-drug Loaded Physically Entrapped Polymeric Micelles
Published on: August 28, 2015
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Methods: Terminology
Stability of Substituted Cyclohexanes
The two chair conformations of cyclohexanes undergo rapid interconversion at room temperature. Both forms have identical energies and stabilities, each comprising equal amounts of the equilibrium mixture. Replacing a hydrogen atom with a functional group makes the two conformations energetically non-equivalent.
For example, in...