Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
A comparative study of Magnetic Resonance (MR) and Computed Tomography (CT) in the pre-implant evaluation
Valentina Pompa1, Sabrina Galasso, Michele Cassetta
1Department of Radiology.
Aim:
A successful implant therapy is based on an accurate assessment of the anatomy of the jaws. The aim of our study was to evaluate the reliability of magnetic resonance imaging (MR) compared with computed tomography (CT) for dental implant planning in respect to bone measurements and to observe and analyze the differences.
Method:
We have studied 30 cases in which scans were performed with CT and MR. The images provided by the MR and CT examinations were delivered to three specialists in oral and maxillofacial radiology to measure the bone height at the specific sites.The measurements obtained by the specialists in MR and CT images were compared using the ANOVA test with a 0.05 significance level.
Result:
In all 30 cases examined, MR images appeared perfectly comparable to CT images. The differences between the measurements from the MR and CT exams varied from 0.04 to 1.1 mm. There were no statistically significant differences (P=0.9).
Conclusion:
The MR, when compared with CT, shown to be reliable in respect to bone measurements for dental implant planning. However, further studies are necessary to determine the technical advantages of Resonance at lower fields, compared with those of CT and MR with medium or high magnetic field.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...