Comparison of three single platform methods for CD34+ hematopoietic stem cell enumeration by flow cytometry
I Marinov1, A Luxova, V Tkacova
1Institute of Hematology and Blood Transfusion, Prague, Czech Republic. luri.Marinov@uhkt.cz
In the present study, we compared three single platform methods for CD34+ hematopoietic stem cell (HSC) enumeration by flow cytometry. For this purpose, we analyzed the performance characteristics and results obtained from different HSC sources. Interlaboratory coefficients of variation (CV) for precision/reproducibility analysis varied from 4.0% to 6.7% / 6.7% to 9.2% for the low and 3.2% to 4.1% / 4.3% to 6.7%, respectively, for the high stem cell control. Correlation between methods ranged from 0.92% to 0.99%; Wilcoxon test showed no significant differences (p > 0.05); Bland-Altman analysis confirmed good agreement between assays (mean bias ranging from -0.48 to 6.91). Our results demonstrate very good intralaboratory correlation and agreement between methods, confirm the major impact of single platform strategy for accurate and reproducible HSC enumeration and suggest that high interlaboratory variability could be influenced by incorrect performance of validated methods.
In the present study, we compared three single platform methods for CD34+ hematopoietic stem cell (HSC) enumeration by flow cytometry. For this purpose, we analyzed the performance characteristics and results obtained from different HSC sources. Interlaboratory coefficients of variation (CV) for precision/reproducibility analysis varied from 4.0% to 6.7% / 6.7% to 9.2% for the low and 3.2% to 4.1% / 4.3% to 6.7%, respectively, for the high stem cell control. Correlation between methods ranged from 0.92% to 0.99%; Wilcoxon test showed no significant differences (p > 0.05); Bland-Altman analysis confirmed good agreement between assays (mean bias ranging from -0.48 to 6.91). Our results demonstrate very good intralaboratory correlation and agreement between methods, confirm the major impact of single platform strategy for accurate and reproducible HSC enumeration and suggest that high interlaboratory variability could be influenced by incorrect performance of validated methods.
More Related Videos
10:25Pan-myeloid Differentiation of Human Cord Blood Derived CD34+ Hematopoietic Stem and Progenitor Cells
Published on: August 9, 2019
09:01Flow Cytometry to Estimate Leukemia Stem Cells in Primary Acute Myeloid Leukemia and in Patient-derived-xenografts, at Diagnosis and Follow Up
Published on: March 26, 2018