Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
Impedance nadir values correlate with barium bolus amount
1Department of Gastroenterology, Cleveland Clinic Foundation, Cleveland, Ohio, USA. h_imam@hotmail.com
Impedance monitoring accurately measures esophageal bolus volume, correlating well with videoesophagram findings. This technique effectively identifies abnormal bolus transit, including failed clearing, reflux, and esophageal escape.
Area of Science:
- Gastroenterology
- Medical Imaging
- Physiology
Background:
- Esophageal bolus transit assessment is crucial for diagnosing swallowing disorders.
- Videoesophagram is a standard method, but impedance monitoring offers a non-radiographic alternative.
Purpose of the Study:
- To evaluate the accuracy of impedance monitoring in quantifying esophageal bolus volume compared to videoesophagram.
- To correlate impedance values with barium area and identify causes of abnormal bolus transit.
Main Methods:
- Simultaneous impedance-manometry-videoesophagram was performed on 80 subjects swallowing barium-saline boluses.
- Impedance falls below 1000 ohms were analyzed and correlated with videofluoroscopic findings of barium presence and area.
Main Results:
- A strong correlation (r=0.83, P<0.001) was found between impedance nadir values and barium area.
- 97% of impedance falls indicated barium presence, consistent across failed clearing, reflux, and esophageal escape.
- Low impedance nadir values (<400 ohms) corresponded to large barium areas, indicating significant bolus volume.
Conclusions:
- Impedance monitoring is a valuable tool for assessing esophageal bolus volume and transit.
- The technique reliably detects abnormal bolus transit, providing quantitative data comparable to videoesophagram.
Related Concept Videos
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Bode Plots Construction