Related Experiment Video
Updated: May 25, 2026

Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
Published on: July 5, 2016
[Nondestructive imaging of elements distribution in biomedical samples by X-ray fluorescence computed tomography]
Qun Yang1, Biao Deng, Wei-Wei Lü
1Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China. yangqun@sinap.ac.cn
Abstract:
X-ray fluorescence computed tomography is a stimulated emission tomography that allows nondestructive reconstruction of the elements distribution in the sample, which is important for biomedical investigations. Owing to the high flux density and easy energy tunability of highly collimated synchrotron X-rays, it is possible to apply X-ray fluorescence CT to biomedical samples. Reported in the present paper, an X-ray fluorescence CT system was established at Shanghai Synchrotron Radiation Facility for the investigations of trace elements distribution inside biomedical samples. By optimizing the experiment setup, the spatial resolution was improved and the data acquisition process was obviously speeded up. The maximum-likelihood expectation-maximization algorithm was introduced for the image reconstruction, which remarkably improved the imaging accuracy of element distributions. The developed system was verified by the test sample and medical sample respectively. The results showed that the distribution of interested elements could be imaged correctly, and the spatial resolution of 150 m was achieved. In conclusion, the developed system could be applied to the research on large-size biomedical samples, concerning imaging accuracy, spatial resolution and data collection time.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

