Related Experiment Video
Updated: May 25, 2026

Murine Bioluminescent Hepatic Tumour Model
Published on: July 17, 2010
Visualisation of liver tumours using hand-held real-time strain imaging: results of animal experiments
D Melodelima1, J Chenot, R Souchon
1Inserm, U1032, Lyon, France. David.Melodelima@inserm.fr
Objective:
Surgical resection is the only curative option for colorectal hepatic metastases. Intra-operative localisation of these metastases during hepatic resection is performed by intra-operative B-mode imaging and palpation. Because liver metastases are stiffer than normal tissues, elastography may be a useful complement to B-mode imaging. This paper reports quantitative measures of the image quality attained during intra-operative real-time elastographic visualisation of liver metastasis.
Methods:
VX2 tumours were implanted in the liver of eight rabbits and were scanned in vivo. Measurements of the tumour dimensions obtained via elastography were compared with those obtained using B-mode imaging and with gross pathology.
Results:
Measurements of tumour diameters were similar when obtained by intra-operative elastography and pathological measurement methods (mean difference±standard deviation, 0.1±0.9 mm). The contrast between tumours and normal tissues was significantly higher (p<0.05) in elastograms (26±10 dB contrast) than in sonograms (1±1 dB contrast). Sensitivity and specificity for detecting tumours using intra-operative elastography were 100% and 88%, respectively, and positive and negative predictive values were 89% and 100%, respectively. In two cases elastograms were able to detect a tumour that was ambiguous in B-mode images.
Conclusion:
Combined hand-held B-mode/strain imaging may provide additional information that is relevant for detection of liver metastases that may be missed by standard B-mode imaging alone, such as small and/or isoechoic tumours.