Related Experiment Video
Updated: May 25, 2026

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Using nanosecond pulse near-field sensing technology for non-contact cardiovascular parameters measurement
Hong-Dun Lin1, Yen-Shien Lee, Yu-Jen Su
1Center for Measurement Standards, Industrial Technology Research Institute, No 321, Sec 2, Kaung Fu Rd, Hsinchu, 30011 Taiwan, ROC. hongdunlin@itri.org.tw
Abstract:
Clinically arterial stiffness has shown that it is the most important cause of cardiovascular complications and also an independent risk factor to several cardiovascular diseases. In routine, there are many preferable non-invasive methods, including pressure-sensitive transducers, applanation tonometry, Doppler ultrasound and MRI, to get insight of cardiovascular condition. However, the operation of traditional monitors is relied on professionals' experience, and also the sensing probes needed to exert pressure to the user directly. The measurement procedure is short-term and easy to cause discomfort. To improve the issues of these measuring techniques, the non-contact and non-invasive measuring method will become an important innovation. In this paper, the novel nanosecond pulse near-field sensing (NPNS) based screening technology, which includes radio frequency (RF) pulse transmission and a flat antenna connected to transceiver of miniature radar, is proposed to monitor cardiovascular activity. A dedicated analysis software is also provided to calculate cardiovascular parameters, including PWV, average systolic time, reflection index (RI), heart and heart rate variability (HRV), for clinical applications. To evaluate the performance, the proposed method was applied on aortic pulse measurement at the body site of chest. As a result, it shows 0.92 correlations with the measurement result from commercial product, and performs the capability of continuously long-term monitoring in real-time.
More Related Videos
08:33Bidirectional Electrical and Optoelectronic Interfaces in Healthy and Ischemic Ex Vivo Rat Hearts
Published on: July 18, 2025
08:51Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
Related Concept Videos
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Pulse
The pulse serves as a clinical indicator...