Related Experiment Video
Updated: May 25, 2026

Temperature-Controlled Assembly and Characterization of a Droplet Interface Bilayer
Published on: April 19, 2021
Integrated heaters for temperature control in disposable bioassay cartridges for use with portable, battery-operated
Luis Ortiz Hernandez1, Haile Negussie, Laura T Mazzola
1Wave 80 Biosciences, Inc, San Francisco, CA 94107, USA. luis.ortiz@wave80.com
Abstract:
Two methods for heating fluids in microliter- to milliliter-scale reaction chambers in disposable bioassay cartridges are analyzed and compared. Inductive heating requires no electrical contact between the energy source and the cartridge and uses a very inexpensive component in the cartridge. Resistive heating with a surface mount component requires electrical interconnection, but is generally conducive to low-cost off-the-shelf components. Typical power consumption for both inductive heating and resistive heating is consistent with battery-powered operation. A finite element model for heating an injection-molded plastic cartridge with a surface-mount resistor has been developed and validated through experiments on a 40 mm × 10 mm × 7.5 mm injection molded polystyrene cartridge with embedded 1 kΩ surface-mount resistors. A model of frequency-dependent heat generation in a novel inductive heating device is also presented.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...