Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
In-vivo Pulse Wave Imaging for arterial stiffness measurement under normal and pathological conditions
Abstract:
Numerous studies have identified arterial stiffening as a strong indicator of cardiovascular pathologies such as hypertension and abdominal aortic aneurysm (AAA). Pulse Wave Imaging (PWI) is a novel, noninvasive ultrasound-based method to quantify regional arterial stiffness by measuring the velocity of the pulse wave that propagates along arterial walls after each left ventricular contraction. The PWI method employs 1D cross-correlation speckle tracking to compute axial incremental displacements, then tracks the position of the displacement wave in the anterior wall of the vessel to estimate pulse wave velocity (PWV). PWI has been validated on straight tube aortic phantoms and aortas of healthy humans as well as normal and AAA murine models. This paper presents and compares preliminary PWI results from normal, hypertensive, and AAA human subjects. PWV was computed in select cases from each subject category. The measured PWV values in hypertensive (N = 5) and AAA (N = 2) subjects were found to be significantly higher than in normal subjects (N = 8). In all subjects, the spatio-temporal profile and waveform morphologies of the pulse wave were generated from the displacement data for visualization and qualitative evaluation of the pulse wave propagation. While the waveforms were found to maintain roughly the same shape in normal subjects, those in the AAA and most hypertensive cases changed drastically along the imaged aortic segment, suggesting non-uniform wall mechanical properties.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...