Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Asymmetric Lipid Bilayer01:35

Asymmetric Lipid Bilayer

Biological membranes show uneven distribution of different types of lipids in the inner and outer layers, resulting in transverse asymmetric membranes. The treatment of the erythrocyte membrane with the enzyme phospholipase confirmed the asymmetric nature of the lipid bilayer. The enzyme hydrolyzes lipids into fatty acids and hydrophilic groups. The phospholipase acts only on the outer layer of the membrane, while the inner layer remains intact. The phospholipase treatment resulted in 80%...
Assembly of the Lipid Bilayer in the ER01:28

Assembly of the Lipid Bilayer in the ER

Biological membranes are more than just a barrier separating cell cytoplasm from the outside environment. They are highly dynamic and help maintain the integrity and physiological stability of the cells as well as membrane-bound organelles. Membranes also play vital roles in cell-to-cell and intracellular communication.
A large chunk of any biological membrane is composed of phospholipids. These lipids have a heterogeneous distribution across different subcellular organelles and even between...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Intravascular Hemolysis and Pulsed-Field Ablation: State of the Art Review.

JACC. Clinical electrophysiology·2026
Same author

Modulation of Contactless High Intensity Pulsed Electromagnetic Field Induced Electroporation and Gene Delivery Efficacy Using Various Nanoparticles.

Bioelectricity·2026
Same author

Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2026
Same author

2026 HRS/EHRA scientific statement on pulsed field ablation for cardiac arrhythmias.

Heart rhythm·2026
Same author

Pulsed field ablation: Disrupting technology in cardiac electrophysiology.

Heart rhythm·2025
Same author

Complexity and Perplexity of Pulsed Field Ablation: An Engineering Perspective.

Arrhythmia & electrophysiology review·2025

Related Experiment Video

Updated: May 25, 2026

Lipid Bilayer Experiments with Contact Bubble Bilayers for Patch-Clampers
07:18

Lipid Bilayer Experiments with Contact Bubble Bilayers for Patch-Clampers

Published on: January 16, 2019

Planar lipid bilayers: observing pore creation and extinction.

Peter Kramar1, Alenka Maček Lebar, Damijan Miklavčič

  • 1University of Ljubljana, Faculty of Electrical Engineering, SI-1000 Ljubljana, Slovenia. peter.kramar@fe.uni-lj.si

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
|January 19, 2012
PubMed
Summary
This summary is machine-generated.

This study models planar lipid bilayers as electrical circuits to analyze transmembrane voltage. The model reveals effective current is lower than applied current, crucial for accurate conductance calculations before breakdown.

More Related Videos

Automated Lipid Bilayer Membrane Formation Using a Polydimethylsiloxane Thin Film
08:23

Automated Lipid Bilayer Membrane Formation Using a Polydimethylsiloxane Thin Film

Published on: July 10, 2016

Ligand Nano-cluster Arrays in a Supported Lipid Bilayer
10:34

Ligand Nano-cluster Arrays in a Supported Lipid Bilayer

Published on: April 23, 2017

Related Experiment Videos

Last Updated: May 25, 2026

Lipid Bilayer Experiments with Contact Bubble Bilayers for Patch-Clampers
07:18

Lipid Bilayer Experiments with Contact Bubble Bilayers for Patch-Clampers

Published on: January 16, 2019

Automated Lipid Bilayer Membrane Formation Using a Polydimethylsiloxane Thin Film
08:23

Automated Lipid Bilayer Membrane Formation Using a Polydimethylsiloxane Thin Film

Published on: July 10, 2016

Ligand Nano-cluster Arrays in a Supported Lipid Bilayer
10:34

Ligand Nano-cluster Arrays in a Supported Lipid Bilayer

Published on: April 23, 2017

Area of Science:

  • Biophysics
  • Electrical Engineering
  • Materials Science

Background:

  • Planar lipid bilayers exhibit non-ideal capacitive behavior, often modeled as a capacitor in parallel with a resistor.
  • Understanding the electrical properties of lipid bilayers is crucial for various biological and technological applications.

Purpose of the Study:

  • To model the electrical behavior of a planar lipid bilayer and its associated measurement system using circuit simulation.
  • To analyze transmembrane voltage changes in response to applied current and investigate pre-breakdown phenomena.
  • To determine the effective current flowing through the lipid bilayer for accurate conductance calculations.

Main Methods:

  • Development of an equivalent electric circuit model for the entire measurement system, including the planar lipid bilayer.
  • Simulation of the model using Spiceopus software.
  • Analysis of simulated transmembrane voltage measurements under a linearly rising current stimulus.

Main Results:

  • The electrical model accurately represented the planar lipid bilayer system.
  • Simulations showed that the effective current passing through the planar lipid bilayer is significantly lower than the current supplied by the generator.
  • This discrepancy is particularly important for calculating conductance from voltage drops observed before bilayer breakdown.

Conclusions:

  • Circuit modeling provides valuable insights into experimental results for planar lipid bilayers.
  • Accurate conductance calculations require accounting for the reduced effective current within the bilayer.
  • The model aids in understanding the electrical characteristics and limitations of planar lipid bilayers prior to electrical breakdown.