Template for preparation of papers for IEEE sponsored conferences & Symposia
H Miura1, Y Shiraishi, T Yambe
1Institute of Development, Aging and Cancer, Tohoku University, Sendai 9808575, JPN. h.miura@idac.tohoku.ac.jp
Abstract:
Rotary blood pumps which have contact-less suspension are small, durable and widely used for left ventricular assist devices (LVADs). In order to design a total artificial heart (TAH) with rotary blood pumps, two pumps one for each ventricle, are controlled independently. Some of the challenges for the development of a TAH includes the requirement of a small size and the anatomical fitting of inlets and outlets which should be arranged closely on the circumference in the same direction. And they should be combined into a unit. In this paper, a helical flow total artificial heart (HFTAH) combing two centrifugal pumps with helical inlet in face is proposed in order to achieve a smaller TAH. To examine the pump performance, a preliminary test model for left ventricle was built, the size of the pump was 69.0mm in diameter and 45.0mm height. The size of the impeller was 44.0mm in diameter and 23.0mm height including a 15.0mm-height hydrodynamic bearing. The pump was externally driven by a direct current motor. 5.0L/min flow rate against 100mmHg pressure difference was obtained, where the total power consumption was 5.0W, the system efficiency was 23% with a rotational speed of 2070rpm. In this system, maximum pressure head, flow rate and efficiency were 420mmHg, 15.0L/min and 26%, respectively. In acute animal experiments with three healthy adult goats, the total biventricular bypass assist system using the pumps was able to maintain the maximum aortic flow at approximately 5.0L/min, and the pulmonary arterial flow at approximately 4.6L/min, the mean aorta pressure was 105mmHg, and the mean pulmonary artery pressure was 51mmHg. The development of the control method is undergoing, and a driving system and the pump aiming at the chronic animal experiments will be developed.
Related Concept Videos
Preparation of Samples for Electron Microscopy
Preparation and Reactions of Thiols
Preparation of Epoxides
Epoxides result from alkene oxidation, which can be achieved by a) air, b) peroxy acids, c) hypochlorous acids, and d) halohydrin cyclization.
Epoxidation with Peroxy Acids
Epoxidation of alkenes via oxidation with peroxy acids involves the conversion of a carbon–carbon double bond to an epoxide using the oxidizing agent meta-chloroperoxybenzoic acid, commonly known as MCPBA. Since the O–O bond of peroxy acids is very weak, the addition of electrophilic oxygen of peroxy acids to...