Related Experiment Video
Updated: May 25, 2026

Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging
Published on: June 30, 2018
Automatic detection of CAP on central and fronto-central EEG leads via Support Vector Machines
Sara Mariani1, Andrea Grassi, Martin O Mendez
1Politecnico di Milano, Dept of Biomedical Engineering, P.zza Leonardo da Vinci 32, 20133 Milan, Italy. sara1.mariani@mail.polimi.it
Abstract:
The aim of this study is to implement a high-accuracy automatic detector of the Cyclic Alternating Pattern (CAP) during sleep. EEG data from four healthy subjects were used. Both the C4-A1 and the F4-C4 leads were analyzed for this study. Seven features were extracted from each of the two leads and two separate studies were performed for each set of descriptors. For both sets, a Support Vector Machine was trained and tested on the data with the Leave One Out cross-validation method. The two final classifications obtained on the two sets were merged, by considering a CAP A phase scored only if it had been recognized both on the central and on the frontal lead. The length of the A phase was then determined by the result on the fronto-central lead. This method leads to encouraging results, with a classification sensitivity on the whole dataset equal to 73.82%, specificity equal to 85.93%, accuracy equal to 84,05% and Cohen's kappa equal to 0.50.