A wearable system for the seismocardiogram assessment in daily life conditions
Marco Di Rienzo1, Paolo Meriggi, Francesco Rizzo
1Biomedical Technology Department, Fondazione Don Carlo Gnocchi, Milano, Italy. mdirienzo@dongnocchi.it
Abstract:
Seismocardiogram (SCG) is the recording of the minute body accelerations induced by the heart activity, and reflects mechanical aspects of heart contraction and blood ejection. So far, most of the available systems for the SCG assessment are designed to be used in a laboratory or in controlled behavioral and environmental conditions. In this paper we propose a modified version of a textile-based wearable device for the unobtrusive recording of ECG, respiration and accelerometric data (the MagIC system), to assess the 3d sternal SCG in daily life. SCG is characterized by an extremely low magnitude of the accelerations (in the order of g × 10(-3)), and is masked by major body accelerations induced by locomotion. Thus in daily life recordings, SCG can be measured whenever the subject is still. We observed that about 30 seconds of motionless behavior are sufficient for a stable estimate of the average SCG waveform, independently from the subject's posture. Since it is likely that during spontaneous behavior the subject may stay still for at least 30 seconds several times in a day, it is expected that the SCG could be repeatedly estimated and tracked over time through a prolonged data recording. These observations represent the first testing of the system in the assessment of SCG out of a laboratory environment, and open the possibility to perform SCG studies in a wide range of everyday conditions without interfering with the subject's activity tasks.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...