Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Robust, beat-to-beat estimation of the true pulse transit time from central and peripheral blood pressure or flow
Guanqun Zhang1, Mingwu Gao, Ramakrishna Mukkamala
1Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA. zhanggu2@msu.edu
Abstract:
We proposed a technique for estimating beat-to-beat pulse transit time (PTT) from central and peripheral blood pressure or flow waveforms based on an arterial tube-load model of wave reflection. The technique effectively estimates PTT from the entire waveforms after mathematically eliminating the reflected wave. So, unlike the conventional foot-to-foot detection technique, this technique should be robust to artifact while revealing the true PTT (i.e., the PTT in absence of wave reflection). We compared the two techniques, as applied to blood pressure and flow waveforms, in terms of the ability of their PTT estimates to correlate with blood pressure (a) during baseline (for which the naturally occurring beat-to-beat changes were small), (b) during low heart rate (wherein wave reflection was profound), and (c) in the presence of actual measurement artifact. In all three cases, the PTT estimates of the arterial tube-load model technique yielded markedly superior correlation to blood pressure.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure