Related Experiment Video
Updated: May 25, 2026

Home-Based Monitor for Gait and Activity Analysis
Published on: August 8, 2019
Continuous monitoring of functional activities using wearable, wireless gyroscope and accelerometer technology
Robert C Wagenaar1, Inbal Sapir, Yuting Zhang
1College of Health and Rehabilitation Sciences, Boston University, Boston, MA 02215, USA. wagenaar@bu.edu
Abstract:
The development of functional activity monitors (FAMs) will allow rehabilitation researchers and clinicians to evaluate treatment efficacy, to monitor compliance to exercise instructions, and to provide real time feedback in the treatment of movement disorders during the performance of daily activities. The purpose of the present study was to develop and test a small sized wearable FAM system comprised of three sensors positioned on the sternum and both thighs, wireless Bluetooth transmission capability to a smartphone, and computationally efficient activity detection algorithms for the accurate detection of functional activities. Each sensor was composed of a tri-axial accelerometer and a tri-axial gyroscope. Computationally efficient activity recognition algorithms were developed, using a sliding window of 1 second, the variability of the tilt angle time series and power spectral analysis. In addition, it includes a decision tree that identifies postures such as sitting, standing and lying, walking at comfortable, slow and fast speeds, transitions between these functional activities (e.g, sit-to-stand and stand-to-sit), activity duration and step frequency. In a research lab setting the output of the FAM system, video recordings and a 3D motion analysis system were compared in 10 healthy young adults. The results show that the agreement between the FAM system and the video recordings ranged from 98.10% to 100% for all postures, transfers and walking periods. There were no significant differences in activity durations and step frequency between measurement instruments.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Gyroscope
Holter Monitor: 24-Hour Monitoring
Gyroscope: Precession
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...