Early detection of spontaneous blood loss using amplitude modulation of Photoplethysmogram
Nandakumar Selvaraj1, Christopher G Scully, Kirk H Shelley
1Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA 01609, USA. nselvaraj@wpi.edu
Abstract:
The present study was designed to investigate can the amplitude modulation (AM) of Photoplethysmogram (PPG) be used as an indicator of blood loss and if so what is the best PPG probe site. PPG from ear, finger and forehead probe sites, standard ECG, and Finapres blood pressure waveforms were continuously recorded from 8 healthy volunteers during baseline, blood withdrawal of 900 ml followed by the blood reinfusion. The instantaneous amplitude modulations present in heart rate (AM(HR)) and breathing rate (AM(BR)) band frequencies of PPG were extracted from high-resolution time-frequency spectrum. HR and pulse pressure showed no significant changes during the protocol. The AM(HR) significantly (P<0.05) decreased at 100 ml through 900 ml blood loss from ear and finger probe sites. The mean percent decrease in AM(HR) at 900 ml blood loss compared to baseline value was 45.2%, 42.0%, and 42.3% for ear, finger and forehead PPG signals, respectively. In addition, significant increases in AM(BR) were found due to blood loss in ear and finger PPG signals. Even without baseline AM(HR) values, 900 ml blood loss detection was shown possible with specificity and sensitivity both 87.5% from ear PPG signals. The present technique has great potential to serve as a valuable tool in the intraoperative and trauma settings to detect hemorrhage.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Measurement of Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.