Contributions of non-spherical hip joint cartilage surface to hip joint contact stress
Dong-Yun Gu1, Fei Hu, Jian-Hei Wei
1Shanghai Key Laboratory of Orthopaedic Implant, Department of Orthopaedics, Shanghai Ninth People’s Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200011, China. dongyungu@gmail.com
Abstract:
The natural non-spherical incongruent hip joint cartilage surface is normally assumed as spherical in shape, which has been extensively applied in orthopedic clinic, hip joint simulation studies and hip joint prosthesis design. The aim of the study was to investigate the contributions of non-spherical incongruent hip joint cartilage surface to the hip joint contact stress, and to assess the effect of simplified spherical assumption on the predicted contact stress. Based on our previous anatomic studies that the acetabular cartilage surface was demonstrated as rotational ellipsoid in shape, three finite element (FE) models involving the natural hip joint cartilage shape, the hip joint cartilage shape replaced by the rotational ellipsoid and the sphere, respectively, were developed using the computed tomography (CT) image data of healthy volunteers. The FE predictions of contact stress on the replaced hip joint cartilage surface were compared with that on the natural hip joint cartilage surface. The result showed that the non-spherical hip joint cartilage surface contributed to the optimal contact stress magnitude and distribution. The replaced fitting spherical surface led to the increased contact stress of hip joint and the uneven distributed patterns of contact stress, whereas the replaced fitting rotational ellipsoid surface was comparatively more consistent with the natural results than the sphere one. The surface fitting error of the replaced rotational ellipsoid was fewer than that of the replaced sphere. These results indicate that the simplified spherical assumption will lead to misestimating the contact mechanics of hip joint, and the rotational ellipsoid model rather than the sphere model may represent the hip joint contact surface applied in the hip joint simulation study and the hip joint prosthesis design.
Related Concept Videos
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and opposite to those on the...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...
Stress Concentrations in Circular Shafts