Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Preclinical Evaluation of <sup>177</sup>Lu-Labeled Anti-CLDN18.2 VHH-Fc for Radioimmunotherapy in Gastric Cancer.

Molecular pharmaceutics·2026
Same author

A 1.5 mm BGO PET detector with DOI measurement.

Physics in medicine and biology·2026
Same author

CD70-targeted platform for diagnosing and treating multiple myeloma.

Journal for immunotherapy of cancer·2026
Same author

Performance Evaluation of SmartBrain: A Wearable PET System for Human Brain Imaging.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2026
Same author

<i>In situ</i> generation of dendritic cell vaccines in 3D printing scaffolds for cancer post-surgical therapy.

National science review·2026
Same author

Dynamic positron emission tomography image reconstruction using spatiotemporal kernel method with deep image prior.

Quantitative imaging in medicine and surgery·2025

Related Experiment Video

Updated: May 25, 2026

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
06:16

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy

Published on: May 1, 2020

Stiffness mapping prostate biopsy samples using a tactile sensor.

Qiyu Peng1, Sadao Omata, Donna M Peehl

  • 1Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA. Qpeng@lbl.gov

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
|January 19, 2012
PubMed
Summary

This study introduces a high-resolution tactile device for mapping cancerous cell stiffness, a potential indicator of cancer aggressiveness. The technology shows promise in differentiating tissue types and understanding tumor mechanics.

More Related Videos

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
06:08

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound

Published on: March 21, 2025

Stiffness Measurement of Soft Silicone Substrates for Mechanobiology Studies Using a Widefield Fluorescence Microscope
07:02

Stiffness Measurement of Soft Silicone Substrates for Mechanobiology Studies Using a Widefield Fluorescence Microscope

Published on: July 3, 2018

Related Experiment Videos

Last Updated: May 25, 2026

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
06:16

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy

Published on: May 1, 2020

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
06:08

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound

Published on: March 21, 2025

Stiffness Measurement of Soft Silicone Substrates for Mechanobiology Studies Using a Widefield Fluorescence Microscope
07:02

Stiffness Measurement of Soft Silicone Substrates for Mechanobiology Studies Using a Widefield Fluorescence Microscope

Published on: July 3, 2018

Area of Science:

  • Biomedical Engineering
  • Oncology
  • Materials Science

Background:

  • Cancer cell stiffness correlates with pathological stage and aggressiveness.
  • Current detection methods lack sensitivity for early-stage cancerous tissues.
  • Elasticity offers potential as a biomarker for cancer aggressiveness.

Purpose of the Study:

  • Evaluate a novel tactile-based device for high-resolution tissue stiffness mapping.
  • Assess the device's sensitivity in differentiating various human prostate tissues (BPH, Cancer, PZ).
  • Identify environmental factors influencing stiffness measurements.

Main Methods:

  • Development of a high-resolution tactile device for mechanical mapping.
  • Application of the device to human prostate tissue samples (BPH, Cancer, PZ).
  • Analysis of environmental factors (humidity, temperature, degradation) on stiffness data.

Main Results:

  • The tactile device successfully distinguished stiffness differences between BPH, Cancer, and PZ tissues.
  • Preliminary results indicate the device's sensitivity for mechanical characterization.
  • Environmental factors like humidity, temperature, and tissue degradation were identified as significant influencers on results.

Conclusions:

  • The developed tactile technology demonstrates potential for high-resolution stiffness mapping of biological tissues.
  • This technology could aid in understanding the mechanical basis of increased stiffness in prostate tumors.
  • Further research may refine the device for clinical applications in cancer diagnostics.