Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Noble Gases02:54

Noble Gases


The elements in group 18 are noble gases (helium, neon, argon, krypton, xenon, and radon). They earned the name “noble” because they were assumed to be nonreactive since they have filled valence shells. In 1962, Dr. Neil Bartlett at the University of British Columbia proved this assumption to be false.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Lack of inhibition by inhalational anesthetics of myocardial contraction dependent on intracellular sodium activity.

Anesthesiology·1996
Same author

Determination of selenium and tellurium in air by atomic-absorption spectrometry.

Talanta·1988
Same author

129I in Missouri thyroids.

Health physics·1982
Same author

Iodine-129 in man, cow and deer.

Health physics·1978
Same author

Iodine-129 in thyroids of grazing animals.

Health physics·1976
Same author

Iodine-129 in thyroid glands.

Health physics·1973

Related Experiment Video

Updated: May 25, 2026

Whole-Body Nanoparticle Aerosol Inhalation Exposures
10:11

Whole-Body Nanoparticle Aerosol Inhalation Exposures

Published on: May 7, 2013

Tellurium and selenium in aerosols

K Y Chiou, O K Manuel

    Environmental Science & Technology
    |January 20, 2012
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber
    09:46

    Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber

    Published on: November 18, 2018

    Extraction and Characterization of Surfactants from Atmospheric Aerosols
    09:34

    Extraction and Characterization of Surfactants from Atmospheric Aerosols

    Published on: April 21, 2017

    Related Experiment Videos

    Last Updated: May 25, 2026

    Whole-Body Nanoparticle Aerosol Inhalation Exposures
    10:11

    Whole-Body Nanoparticle Aerosol Inhalation Exposures

    Published on: May 7, 2013

    Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber
    09:46

    Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber

    Published on: November 18, 2018

    Extraction and Characterization of Surfactants from Atmospheric Aerosols
    09:34

    Extraction and Characterization of Surfactants from Atmospheric Aerosols

    Published on: April 21, 2017