Related Experiment Video
Updated: May 25, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
A novel dentin bond strength measurement technique using a composite disk in diametral compression
Shih-Hao Huang1, Lian-Shan Lin, Joel Rudney
1Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taiwan.
A novel modified Brazilian disk test effectively measures the bond strength of intracanal posts to dentin. This new method offers simpler preparation and more reliable results for predicting dental restoration failure.
Area of Science:
- Biomaterials Science
- Dental Materials Science
- Mechanical Engineering
Background:
- Predicting clinical failure of dental restorations bonded to dentin requires improved methods.
- Current techniques for measuring dentin bond strength have significant limitations, including stress distribution deviations and high variability.
Purpose of the Study:
- To evaluate a novel test specimen and method for measuring post-dentin interfacial bond strength.
- To assess the feasibility of the modified Brazilian disk test for assessing intracanal post bonding.
Main Methods:
- A modified Brazilian disk test was employed using resin composite disks containing dentin slices with or without intracanal posts.
- Diametral compression testing was performed, coupled with advanced non-destructive techniques: acoustic emission (AE) and digital image correlation (DIC).
- Finite-element analysis (FEA) was integrated with experimental data to calculate bond/tensile strengths.
Main Results:
- Digital image correlation (DIC) identified initial strain concentration at the post-dentin interface, coinciding with the first acoustic emission (AE) signals.
- Calculated bond/tensile strengths were: 11.2 MPa (fiber posts), 12.9 MPa (metal posts), 8.9 MPa (direct resin fillings), and 82.6 MPa for dentin.
- The modified Brazilian disk test demonstrated simpler specimen preparation, consistent failure modes, and reduced variability in bond strength measurements.
Conclusions:
- The feasibility of using a composite disk in diametral compression to measure post-dentin bond strength has been established.
- This novel method provides a more reliable and consistent approach to evaluating the interfacial bond strength critical for dental restoration longevity.
- The findings support the potential of this technique for predicting clinical failure in dentin-bonded restorations.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024