Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

399
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over...
399
Feedback control systems01:26

Feedback control systems

642
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
642
Transient and Steady-state Response01:24

Transient and Steady-state Response

478
In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
478
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

397
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
397
Classification of Systems-II01:31

Classification of Systems-II

433
Continuous-time systems have continuous input and output signals, with time measured continuously. These systems are generally defined by differential or algebraic equations. For instance, in an RC circuit, the relationship between input and output voltage is expressed through a differential equation derived from Ohm's law and the capacitor relation,
433
Electro-mechanical Systems01:19

Electro-mechanical Systems

1.5K
Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
1.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Precision Exercise for Breast Cancer-Related Outcomes: Towards Personalised Training Based on Tumour, Treatment and Patient Characteristics.

Sports medicine (Auckland, N.Z.)·2026
Same author

Integrative Oncology for Prostate Cancer: A Narrative Review.

Seminars in radiation oncology·2026
Same author

Response to Comment on "Periodizing Exercise Medicine Prescription for Patients with Cancer: A Narrative Opinion".

Sports medicine (Auckland, N.Z.)·2026
Same author

Accelerometry daily steps count is associated with overall survival in malignant pleural effusion patients.

Respiratory medicine·2026
Same author

Precision nutrition in breast cancer: Towards patient- and tumour-informed dietary strategies.

Clinical nutrition (Edinburgh, Scotland)·2026
Same author

Feasibility and Preliminary Efficacy of Integrative Neuromuscular Training for Childhood Cancer Survivors: A Pilot Study.

Pediatric blood & cancer·2026

Related Experiment Video

Updated: Jan 1, 2026

All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
11:33

All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics

Published on: January 19, 2018

10.2K

Advances in electronic timing systems: considerations for selecting an appropriate timing system.

Jacob E Earp1, Robert U Newton

  • 1School of Exercise and Health Sciences, Edith Cowan University, Joondalup, Western Australia, Australia. j.earp@ecu.edu.au

Journal of Strength and Conditioning Research
|January 24, 2012
PubMed
Summary

Accurate sprint timing is crucial for performance analysis. Dual-photocell and signal processing systems significantly reduce errors from false signals compared to single photocell systems, ensuring reliable training adaptation tracking.

More Related Videos

Multifunctional Setup for Studying Human Motor Control Using Transcranial Magnetic Stimulation, Electromyography, Motion Capture, and Virtual Reality
08:09

Multifunctional Setup for Studying Human Motor Control Using Transcranial Magnetic Stimulation, Electromyography, Motion Capture, and Virtual Reality

Published on: September 3, 2015

11.4K
Assessing the Multiple Dimensions of Engagement to Characterize Learning: A Neurophysiological Perspective
13:57

Assessing the Multiple Dimensions of Engagement to Characterize Learning: A Neurophysiological Perspective

Published on: July 1, 2015

13.0K

Related Experiment Videos

Last Updated: Jan 1, 2026

All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
11:33

All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics

Published on: January 19, 2018

10.2K
Multifunctional Setup for Studying Human Motor Control Using Transcranial Magnetic Stimulation, Electromyography, Motion Capture, and Virtual Reality
08:09

Multifunctional Setup for Studying Human Motor Control Using Transcranial Magnetic Stimulation, Electromyography, Motion Capture, and Virtual Reality

Published on: September 3, 2015

11.4K
Assessing the Multiple Dimensions of Engagement to Characterize Learning: A Neurophysiological Perspective
13:57

Assessing the Multiple Dimensions of Engagement to Characterize Learning: A Neurophysiological Perspective

Published on: July 1, 2015

13.0K

Area of Science:

  • Sports Science
  • Biomechanics
  • Performance Measurement

Background:

  • Accurate performance tracking is essential for athletic development.
  • Traditional electronic timing systems can introduce errors, particularly in sprint measurements.
  • Errors arise when body parts (arms/legs) trigger timing gates before the torso.

Purpose of the Study:

  • To evaluate the accuracy of different electronic timing systems for 10-m sprints.
  • To compare the incidence of false signals across single photocell (SP), dual-photocell (DP), and signal-processed systems.
  • To determine the most reliable system for measuring short sprint performance and training adaptations.

Main Methods:

  • Ten subjects completed ten 10-m sprints.
  • Split times were recorded using three systems: SP, DP without processing, and a signal-processed gate.
  • False signals and differences between systems were analyzed.

Main Results:

  • Dual-photocell systems generated fewer false signals than single photocell systems (7 vs. 14).
  • Signal processing completely eliminated false signals across all trials.
  • Mean differences between systems were small (9-17 ms), but standard deviations varied (12-42 ms) due to false signals.

Conclusions:

  • For 10-m sprints, timing systems that minimize or eliminate false signals (DP or signal processing) are necessary.
  • Single photocell systems without internal processing are inappropriate for short sprint timing.