Related Experiment Video
Updated: Feb 15, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Determination of 14 amines in air samples using midget impingers sampling followed by analysis with ion
Marie Verriele1, Hervé Plaisance, Laurence Depelchin
1Université Lille Nord de France, F-59000 Lille, France.
Abstract:
An Ion Chromatography-Mass Spectrometry (IC-MS) method was developed for the simultaneous quantification of 14 volatile amines in air. The method includes collection of compounds into two midget impingers in a row filled with 15 ml of ultrapure water. The analytical performances with mass spectrometry detection were compared to those obtained with classical conductivity detection. The use of mass spectrometry detection (in SIM mode) overcomes most of the coelutions encountered with conductivity detection. Although the linearity domain of calibrations is reduced for the MS detection as compared with the CD detection, the detection limits in MS detection are highly lowered allowing the quantification of amines at the levels of μg m(-3) in air with a good accuracy for most compounds (RSD of less than 10%). This method was successfully applied to the analysis of amines released from polyurethane foams. Seven amines were identified and some in high concentrations, like dimethylaminoethanol, NIAX and TEDA.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Mass Spectrometry of Amines
Tandem Mass Spectrometry
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...