Related Experiment Video
Updated: May 25, 2026

Characterization of Proteins by Size-Exclusion Chromatography Coupled to Multi-Angle Light Scattering (SEC-MALS)
Published on: June 20, 2019
Accurate determination of extra-column band broadening using peak summation
Matthias Verstraeten1, Anuschka Liekens, Gert Desmet
1Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS-IR), Brussels, Belgium.
Abstract:
The present contribution addresses the problem of the accurate determination of the extra-column band-broadening dispersion by applying the method of moments (MOM) on pulse response experiments. The MOM provides the only mathematically rigorous way to determine the variance of a pulse response, but suffers from the fact that the obtained variance values usually depend very strongly and unpredictably on the selected integration boundaries. In the present study, it is investigated whether the MOM cannot be made more accurate by repeating the pulse response experiment a number of times, then add all measured peaks (after retention time alignment) and subsequently perform the integration on this summed peak. Testing this approach for a number of different integration boundary detection methods consistently more accurate results are obtained than when the different repeat response pulses are integrated individually and the variances are averaged afterwards. It was also found that adding five repeats already leads to a significant improvement of the variance estimate, whereas the addition of 10-20 repeats is needed before the variance estimate converges to a steady value.
Related Concept Videos
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
¹H NMR Signal Integration: Overview
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
NMR Spectrometers: Resolution and Error Correction