Related Experiment Video
Updated: May 25, 2026

Single Incision Plus One Port Laparoscopic Proximal Gastrectomy with Double Channel Anastomosis for Gastric Cancer Treatment
Published on: December 27, 2024
Management of malignant gastric outlet obstruction with a modified triple-layer covered metal stent
Hiroyuki Isayama1, Takashi Sasaki, Yousuke Nakai
1Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Background:
A high incidence of migration with covered metal stents has been reported in malignant gastric outlet obstruction (GOO). A newly modified, partially covered, triple-layer nitinol stent was developed that has a longer uncovered portion (5-15 mm) to prevent stent migration.
Objective:
To estimate the efficacy and safety of the modified covered, triple-layer metal stent.
Design:
Multicenter, prospective cohort study.
Setting:
Three tertiary referral centers.
Patients:
Fifty consecutive patients (26 with pancreatic carcinoma, 14 with gastric carcinoma, 9 with cholangiocarcinoma, 1 with a metastatic node) who presented with symptomatic unresectable malignant GOO between April 2007 and March 2010.
Interventions:
Endoscopic placement of the modified covered, triple-layer metal stent.
Main Outcome Measurements:
The primary endpoint was to improve the GOO scoring system (GOOSS) score. Secondary endpoints were success rate, patency, and complications.
Results:
The median GOOSS score improved significantly (P < .0001) after stenting (from 0 to 3). The technical and clinical success rates were 100% and 90%, respectively. Stent occlusion by tumor overgrowth or ingrowth at the uncovered portion developed in 5 patients (10%). Asymptomatic stent migration occurred in 3 patients (6%) receiving chemotherapy at 95, 230, and 553 days after stent placement, but these patients tolerated solid food 68, 260, and 142 days after stent migration, respectively. Other complications occurred in 1 patient with insufficient expansion, cholangitis, and pancreatitis. No procedure-related deaths occurred.
Limitations:
A single-arm study in tertiary-care centers.
Conclusions:
The modified covered, triple-layer metal stent was effective and safe for managing malignant GOO and can prevent tumor ingrowth and stent migration. (
Clinical Trial Registration Number:
UMIN000004566.).
Related Concept Videos
Peptic Ulcer Disease V: Surgical Management and Nursing Care
Surgical Interventions for Peptic Ulcer Disease
Enteral Nutrition II: Nasointestinal and Gastrostomy Feeding
Nasointestinal Feeding
Nasointestinal feeding involves placing a tube through...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...