Safety of carbon dioxide digital subtraction angiography
John M Moos1, Sung W Ham, Sukgu M Han
1Division of Vascular Surgery and Endovascular Therapy, CardioVascular Thoracic Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.
Objective:
Reports of fatality following carbon dioxide digital subtraction angiography (CO2-DSA) have raised concerns regarding its safety. This study reviews the safety of CO2-DSA.
Design:
Single-institution retrospective review.
Setting:
Tertiary care teaching hospital in Los Angeles, California.
Patients:
A total of 951 patients who underwent 1007 CO2-DSA procedures during a 21-year period.
Main Outcome Measures:
Preprocedure and postprocedure creatinine values and periprocedural morbidity and mortality.
Results:
A total of 632 arterial CO2-DSA were performed; 527 were aortograms with or without extremity runoff; 100, extremity alone; and 5, pulmonary. Venous CO2-DSA included 187 inferior vena cavagrams, 182 hepatic or visceral, 5 extremity venograms, and 1 superior vena cavagram. Associated endovascular procedures were performed in 499 cases; 162 were arterial interventions including 62 endovascular aneurysm repairs, 53 visceral or renal percutaneous angioplasty with/without stent, 41 extremity percutaneous angioplasty with or without a stent, and 4 cases of thrombolysis or embolization; 176 caval filters, 98 transjugular intrahepatic portosystemic shunts, 54 transjugular liver biopsies, and 9 other venous interventions. The mean preprocedure creatinine level was 2.1 mg/dL; postprocedure, 2.1 mg/dL (P = .56). There were a total of 61 (6.1%) procedural complications including 4 (0.4%) mortalities. Two were procedure-related complications: 1, suppurative pancreatitis following aortogram; and 2, hepatic bleed following failed transjugular intrahepatic portosystemic shunts. Two were attributable to patient disease; 1, metastatic adenocarcinoma; and 2, refractory, end-stage cardiomyopathy.
Conclusion:
Carbon dioxide digital subtraction angiography is a versatile technique that can be safely used for diagnostic and therapeutic endovascular procedures. Morbidity and mortality are acceptable with preservation of renal function. Thus, CO2-DSA is a safe alternative to iodinated contrast.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies VII: Vascular Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...