Contrast timing in computed tomography: effect of different contrast media concentrations on bolus geometry
Andreas H Mahnken1, Gregor Jost, Peter Seidensticker
1Department of Diagnostic and Interventional Radiology, RWTH Aachen University, Germany. andreas.mahnken@rwth-aachen.de
Objective:
To assess the effect of low-osmolar, monomeric contrast media with different iodine concentrations on bolus shape in aortic CT angiography.
Materials And Methods:
Repeated sequential computed tomography scanning of the descending aorta of eight beagle dogs (5 male, 12.7±3.1kg) was performed without table movement with a standardized CT scan protocol. Iopromide 300 (300mgI/mL), iopromide 370 (370mgI/mL) and iomeprol 400 (400mgI/mL) were administered via a foreleg vein with an identical iodine delivery rate of 1.2gI/s and a total iodine dose of 300mgI/kg body weight. Time-enhancement curves were computed and analyzed.
Results:
Iopromide 300 showed the highest peak enhancement (445.2±89.1 HU), steepest up-slope (104.2±17.5 HU/s) and smallest full width at half maximum (FWHM; 5.8±1.0s). Peak enhancement, duration of FWHM, enhancement at FWHM and up-slope differed significantly between iopromide 300 and iomeprol 400 (p<0.05). Except for enhancement at FWHM there were no significant differences between iopromide 300 and iopromide 370 and iopromide 370 and iomeprol 400 (p>0.05).
Conclusions:
Low viscous iopromide 300 results in a better defined bolus with a significantly higher peak enhancement, steeper up-slope and smaller FWHM when compared to iomeprol 400. These characteristics potentially affect contrast timing.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET