Central aortic blood pressure and augmentation index during normal pregnancy
Mika Fujime1, Takuji Tomimatsu, Yuko Okaue
1Department of Obstetrics and Gynecology, Osaka University Graduate School of Medicine, Suita, Japan. tomimatsu@gyne.med.osaka-u.ac.jp
The current study tested the hypothesis that pregnancy-related changes are more pronounced in central hemodynamics, and both central aortic systolic blood pressure (cSBP) and augmentation index (AIx) are independent from brachial systolic blood pressure (bSBP) in normal pregnant subjects. In 830 healthy pregnant women from 12 to 36 weeks gestation, we measured cSBP and AIx-75 (AIx at heart rate of 75 beats per minute) non-invasively by pulse waveforms of the radial artery using an automated applanation tonometric system. In 69 pregnant women, we recorded these data longitudinally. cSBP and AIx-75 significantly declined during pregnancy, reaching its nadir in mid-pregnancy and rising towards term. Pregnancy-related changes were more pronounced in AIx-75 compared with cSBP, but less evident in bSBP. AIx-75, but not cSBP, was independent from bSBP throughout pregnancy. cSBP and AIx-75, but not bSBP, were significantly increased in healthy pregnant women older than 35 years. This study established normal values for pulse wave analysis parameters throughout pregnancy, and indicated that pulse wave analysis might offer additional and independent information about maternal arterial compliance to conventional brachial blood pressure measurements. These data may be used as the basis for further investigation into the role of pulse wave analysis in the assessment, management and prediction of disorders, which might interfere with pregnancy-related cardiovascular adaptations.
The current study tested the hypothesis that pregnancy-related changes are more pronounced in central hemodynamics, and both central aortic systolic blood pressure (cSBP) and augmentation index (AIx) are independent from brachial systolic blood pressure (bSBP) in normal pregnant subjects. In 830 healthy pregnant women from 12 to 36 weeks gestation, we measured cSBP and AIx-75 (AIx at heart rate of 75 beats per minute) non-invasively by pulse waveforms of the radial artery using an automated applanation tonometric system. In 69 pregnant women, we recorded these data longitudinally. cSBP and AIx-75 significantly declined during pregnancy, reaching its nadir in mid-pregnancy and rising towards term. Pregnancy-related changes were more pronounced in AIx-75 compared with cSBP, but less evident in bSBP. AIx-75, but not cSBP, was independent from bSBP throughout pregnancy. cSBP and AIx-75, but not bSBP, were significantly increased in healthy pregnant women older than 35 years. This study established normal values for pulse wave analysis parameters throughout pregnancy, and indicated that pulse wave analysis might offer additional and independent information about maternal arterial compliance to conventional brachial blood pressure measurements. These data may be used as the basis for further investigation into the role of pulse wave analysis in the assessment, management and prediction of disorders, which might interfere with pregnancy-related cardiovascular adaptations.
Related Concept Videos
Measurement of Blood Pressure
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Hormonal Regulation
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.