The continued development of flow-controlled two-dimensional gas chromatography (2-D GC) is reviewed, with a special emphasis on results published from 2001 through 2011. Heart-cutting 2-D GC continues to be used for isolating selected components in complex mixtures. The programmable and highly precise flows and temperatures produced by modern gas chromatographs have made it easier to selectively transfer analytes to the secondary column and to backflush unwanted components from the primary column. Several new Deans switch interfaces for performing heart-cutting 2-D GC have been introduced, with most attention given to devices that integrate the flow connections into a single unit. Heart-cutting 2-D GC has been used to isolate analytes in a wide variety of complex mixtures including fuels, industrial feedstocks, fragrances, and environmental extracts. Valve-based comprehensive 2-D GC (GC×GC) was also actively developed in the past decade. Valve-based modulation is a simple way to generate GC×GC separations without using cryogenic fluids. More than ten new valve-based modulators were introduced. Diaphragm valves fitted with sample loops are the most common low duty cycle modulators, whereas fluidic modulators that employ differential flow conditions are the most common high duty cycle modulators. Applications of valve-based GC×GC include analysis of hydrocarbon mixtures, essential oils, and environmental samples.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II