Related Experiment Video
Updated: May 25, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Determination of phenols with ion chromatography-online electrochemical derivatization based on porous
Shuchao Wu1, Bingcheng Yang, Lingling Xi
1Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang, China.
Abstract:
The current study describes the determination of phenols using ion chromatography-online electrochemical derivatization-fluorescence detection (IC/ED/FD). Six model phenols including 4-methylphenol (pMP), 2, 4-dimethylphenol (DMP), 4-tert-butylphenol (TBP), 4-hydroxylphenolacetic acid (pHPA), 4-acetamidophenol (pAAP), and phenol (P) were well separated on an anion-exchange column under ion exchange mode using NaOH with small amount of acetonitrile added as eluent. Online electrochemical derivatization performed via a laboratory-made electrolytic cell (EC), consisting of porous titanium electrode and cation-exchange membrane (CEM), allows the oxidation products that are strongly fluorescent to be detected by the fluorescence detector. NaOH eluent used in the present method matches well with the maximal fluorescence intensity obtained at alkaline condition for oxidized phenols, thus the addition of specific buffer solution after oxidation encountered in previous report could be eliminated. This process leads to a simplified procedure. The proposed method was sensitive to the limits of detection in the range of 0.4 μg/L and 3.8 μg/L and the limits of quantification between 1.2 μg/L and 13 μg/L due to the strong electro-oxidation capacity of porous titanium electrode, as well as the implementation of time-programmed potential over EC. The linear ranges were 2.0-1.0 × 10(4) μg/L for pAAP and DMP, and 10-1.0 × 10(4) μg/L for P, pMP, pHPA, and TBP, respectively. The relative standard deviations range from 0.9% to 4.8%. The utilization of the method was demonstrated by the analysis of real samples. The average spiked recoveries of target analytes in pool water were 81.0-118%.
More Related Videos
11:44Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Photoluminescence: Applications
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...