Approaches for non-invasive assessment of endothelial function: focus on peripheral arterial tonometry
J J Kandhai-Ragunath1, H T Jørstad, F H A F de Man
1Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Haaksbergerstraat 55, 7513ER, Enschede, the Netherlands.
Abstract:
The arterial endothelium is a complex organ that modulates vascular tone by release of various substances to control perfusion. Endothelial function reflects vascular ageing and health. Already at the earliest stages of atherosclerosis the delicate balance between arterial constriction and relaxation is disturbed. Therefore, non-invasive assessment of endothelial function is a means to identify patients at increased cardiovascular risk, even at levels of disease that cannot be identified with classical imaging techniques that depict arterial wall and/or lumen or with functional assessment of ischaemia. Currently, there is an increasing interest in the early recognition of endothelial dysfunction to streamline and optimise preventive therapeutic measures. In this article, several methods for the assessment of endothelial function are briefly reviewed. In particular, we discuss the fast bed-side assessment of endothelial function by the reactive hyperaemia peripheral arterial tonometry (RH-PAT) method.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: