Related Experiment Video
Updated: May 25, 2026

Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model
Published on: September 14, 2009
Identification of vulnerable plaque in a stented coronary segment 17 years after implantation using optical coherence
Jeong Hoon Yang1, Kyeongmin Byeon, Hyeon-Cheol Gwon
1Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, Seoul 135-710, Korea.
Abstract:
A patient presented with exertional chest pain two months prior to admission. Coronary angiography revealed a subocclusive stenosis within the boundaries of the stent. Optical coherence tomography showed remarkable intimal growth inside the stent, which demonstrated a heterogeneous appearance including low-intensity areas. These findings were congruent with the morphology of fibroatheroma in the native coronary artery and suggested that new atherosclerotic progression of the intima within the stent had occurred over 17 years following bare metal stent implantation. To the best of our knowledge, this is one of the most delayed instances of a bare metal stent restenosis described in the medical literature.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies