Related Experiment Video
Updated: May 25, 2026

05:37
Experimental Model of Ligature-Induced Peri-Implantitis in Mice
Published on: May 17, 2024
Short implants (6 mm) installed immediately into extraction sockets: an experimental study in dogs
Eriberto Bressan1, Stefano Sivolella, Zoraya Almagro Urrutia
1Faculty of Dentistry, University of Medical Science, La Habana, Cuba.
Clinical Oral Implants Research
|February 11, 2012
Summary
Shorter dental implants (6 mm) demonstrate comparable osseointegration to longer implants (11 mm) when placed immediately after tooth extraction. This finding suggests implant length may not significantly impact initial bone-to-implant contact.
Area of Science:
- Dental Implantology
- Biomaterials Science
- Oral Surgery
Background:
- Immediate implant placement after tooth extraction is a common dental procedure.
- Osseointegration, the direct contact between bone and implant, is crucial for long-term implant success.
- The influence of implant length on osseointegration in immediate extraction sockets requires further investigation.
Purpose of the Study:
- To compare the osseointegration of 6 mm implants versus 11 mm implants placed immediately into extraction sockets.
- To evaluate the effect of implant length on bone-to-implant contact and surrounding tissue parameters.
Main Methods:
- A comparative study was conducted on six Labrador dogs.
- Implants of 6 mm and 11 mm lengths were placed in contralateral premolar extraction sockets.
- Histological analysis was performed after a 4-month healing period to assess osseointegration.
Main Results:
- No statistically significant differences were observed in hard and soft tissue parameters between the 6 mm and 11 mm implants.
- Bone-to-implant contact in the apical region was similar for both implant lengths.
- A trend towards a more apical bone crest was noted with shorter implants, though not statistically significant.
Conclusions:
- Shorter implants (6 mm) achieve comparable osseointegration to longer implants (11 mm) in immediate extraction sockets.
- Implant length does not appear to be a critical factor for initial osseointegration in this model.
- Further research may explore long-term outcomes and different clinical scenarios.