Related Experiment Video
Updated: Aug 17, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
[Apnea and oxygen desaturation following nitrous oxide inhalation]
S Satoh1, S Matsukawa, K Hoshi
1Department of Anesthesiology, Tohoku University School of Medicine, Sendai.
Abstract:
Apnea and desaturation following nitrous oxide inhalation were studied in seven adult volunteers breathing spontaneously. Arterial oxygen saturation (SpO2), end-tidal CO2 concentration in the nasal cavity and respiratory patterns were measured in volunteers breathing air after N2O (50% or 67%) + O2. SpO2 was measured with Biox 3700 and end-tidal CO2 concentration was measured with Normocap, and respiratory patterns were recorded with RESPIGRAPH. After breathing N2O, two volunteers had frequent apnea (greater than 20 sec) accompanied by desaturation (SpO2 less than 90%). The lowest value of SpO2 was 82%. When the apnea occurred, the airway seemed to be open and end-tidal CO2 concentration values were lower than those before N2O inhalation. The authors considered that this kind of apnea was due to several factors, such as hypocapnia caused by hyperventilation during N2O anesthesia, dilution of alveolar O2 and CO2 during N2O excretion, loss of consciousness by N2O, and depression of CO2 ventilatory response by N2O. Inhalation of O2 at high concentrations for five minutes could improve the hypocapnia and prevent the apnea.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Inhalational Anesthetics: Overview
Hyperpnea and Hyperventilation
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-IV
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...