Related Experiment Video
Updated: May 25, 2026

Sample Preparation and Relative Quantitation using Reductive Methylation of Amines for Peptidomics Studies
Published on: November 4, 2021
Increasing peptide identifications and decreasing search times for ETD spectra by pre-processing and calculation of
Viswanadham Sridhara1, Dina L Bai, An Chi
1National Library of Medicine, NIH, Bethesda, Maryland, USA. lewis.geer@nih.gov.
Background:
Electron Transfer Dissociation [ETD] can dissociate multiply charged precursor polypeptides, providing extensive peptide backbone cleavage. ETD spectra contain charge reduced precursor peaks, usually of high intensity, and whose pattern is dependent on its parent precursor charge. These charge reduced precursor peaks and associated neutral loss peaks should be removed before these spectra are searched for peptide identifications. ETD spectra can also contain ion-types other than c and z˙. Modifying search strategies to accommodate these ion-types may aid in increased peptide identifications. Additionally, if the precursor mass is measured using a lower resolution instrument such as a linear ion trap, the charge of the precursor is often not known, reducing sensitivity and increasing search times. We implemented algorithms to remove these precursor peaks, accommodate new ion-types in noise filtering routine in OMSSA and to estimate any unknown precursor charge, using Linear Discriminant Analysis [LDA].
Results:
Spectral pre-processing to remove precursor peaks and their associated neutral losses prior to protein sequence library searches resulted in a 9.8% increase in peptide identifications at a 1% False Discovery Rate [FDR] compared to previous OMSSA filter. Modifications to the OMSSA noise filter to accommodate various ion-types resulted in a further 4.2% increase in peptide identifications at 1% FDR. Moreover, ETD spectra when searched with charge states obtained from the precursor charge determination algorithm is shown to be up to 3.5 times faster than the general range search method, with a minor 3.8% increase in sensitivity.
Conclusion:
Overall, there is an 18.8% increase in peptide identifications at 1% FDR by incorporating the new precursor filter, noise filter and by using the charge determination algorithm, when compared to previous versions of OMSSA.
More Related Videos
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

