[Effect of surface treating methods on the shear strength of luting cements to Cercon zirconia]
Yong-gang Ma1, Xu-liang Deng, Feng Xian
1Department of Yuquan Hospital of Qinghua University, Beijing 100049, China. m.y.g.6212@163.com
Objective:
To study the effect of surface treating methods on the shear strength of Panavia F luting cements to Cercon zirconia.
Methods:
Forty sample disc of Cercon zirconia with 20 mm in diameter and 4 mm in height were prepared. Another 40 sample discs with 5 mm in diameter and 4 mm in height were also prepared Both of the two types of samples were randomly devided into four groups A, B, C, and D in which different surface treatments were delivered. In group A samples was treated with 600# sand paper, and in group Bwith sand blasting, and silanization in group C, and sand blasting plus silanization in group D. All samples were bonded with Panavia F luting cement under the aid of glass mould. The value of shear strength was measured and statistically analysed.
Results:
The shear strength of four groups of samples were (21.50 ± 1.98), (23.68 ± 2.31), (20.69 ± 1.55), (24.01 ± 2.19) MPa respectively. The population mean was not equal. There was no significant difference between 600# sand paper treated group and silanization group, nor between sand blasting group and sand blasting plus silanization group.
Conclusions:
Sand blasting is a effective means to increase the shear strength, and 600# sand paper treatment and silanization can't increase the shear strength.
More Related Videos
04:32A Uniform Shear Assay for Human Platelet and Cell Surface Receptors via Cone-plate Viscometry
Published on: June 5, 2019
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Hydration of Cement
Soundness of Cement
Portland Cement
Fineness of Cement
Direct...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...