Related Experiment Video
Updated: May 25, 2026

Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012
Quantification of prothrombin in human plasma amplified by autocatalytic reaction
Ana Virel1, Laura Saa, Valeri Pavlov
1CIC biomaGUNE, Parque Tecnológico de San Sebastián, Paseo Miramón 182, 20009, San Sebastián, Spain.
Abstract:
By site directed mutagenesis, we have produced recombinant mutants of human and mouse prethrombin-2 which are able to convert themselves autocatalytically into α-thrombin. We also have created a new method to amplify the signal of bioanalytical assays based on the autocatalytic activation of these mutated proenzymes. The activation of the mutants by active α-thrombin triggers an autocatalytic reaction which leads to more active thrombin resulting in the amplification of the readout signal. Addition of mutated mouse prethrombin-2 into the conventional assay for prothrombin level in human plasma, employing ecarin and the fluorogenic substrate, resulted in improvement of the detection limit by 2 orders of magnitude.
More Related Videos
08:01The Nijmegen Hemostasis Assay: Simultaneous Fluorogenic Measurement of Thrombin and Plasmin Generation in a Single Well
Published on: February 27, 2026
08:50Thrombus Profiling Assay: A Microfluidics-Based Platform for Comprehensively Characterizing Biomechanical Thrombogenesis
Published on: January 9, 2026