Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Fundamentals of the gut for capsule engineers.

Progress in biomedical engineering (Bristol, England)·2026
Same author

Differences in the mechanical properties of intestinal tissue based on preservation freezing duration and temperature.

Journal of the mechanical behavior of biomedical materials·2024
Same author

A Novel Articulating Chip-on-Tip Endoscope for Dynamic Middle Ear Surgical Visualization.

IEEE transactions on bio-medical engineering·2023
Same author

Glycerol as a precursor for hepatic de novo glutathione synthesis in human liver.

Redox biology·2023
Same author

Deep Learning Segmentation of the Right Ventricle in Cardiac MRI: The M&Ms Challenge.

IEEE journal of biomedical and health informatics·2023
Same author

Testing oxygenated microbubbles via intraperitoneal and intrathoracic routes on a large pig model of LPS-induced acute respiratory distress syndrome.

Physiological reports·2022

Related Experiment Video

Updated: May 24, 2026

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
03:07

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial

Published on: August 19, 2025

Single-port-access surgery with a novel magnet camera system.

Benjamin S Terry1, Zachary C Mills, Jonathan A Schoen

  • 1University of Colorado, Boulder, CO 80309, USA. benjamin.terry@colorado.edu

IEEE Transactions on Bio-Medical Engineering
|February 16, 2012
PubMed
Summary

A new magnet camera system enhances single-port access laparoscopic surgery (SPA) by integrating light and video, freeing up space for surgical tools and improving visualization.

More Related Videos

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
09:13

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

Published on: April 21, 2013

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
12:25

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position

Published on: September 16, 2022

Related Experiment Videos

Last Updated: May 24, 2026

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
03:07

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial

Published on: August 19, 2025

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
09:13

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

Published on: April 21, 2013

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
12:25

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position

Published on: September 16, 2022

Area of Science:

  • Minimally Invasive Surgery
  • Surgical Instrumentation
  • Medical Imaging

Background:

  • Single-port access laparoscopic surgery (SPA) offers benefits but faces challenges with instrument crowding and limited visualization.
  • Traditional SPA setups often require a dedicated channel for the laparoscope, restricting the number of surgical tools that can be used.
  • Improving camera system mobility and reducing interference are key to optimizing SPA procedures.

Purpose of the Study:

  • To design, build, and test a novel camera system specifically for single-port access laparoscopic surgery.
  • To enhance SPA by eliminating the need for a dedicated laparoscope channel within the port.
  • To increase the field of view and reduce tool-camera interference during SPA.

Main Methods:

  • Development of a compact, integrated light source and video camera system (magnet camera).
  • Insertion of the device through a 26-mm umbilical incision, separate from the SPA port.
  • Mounting the camera system via a rigid ring/cantilever bar attached to the SPA port or using an external magnetic handle.

Main Results:

  • The magnet camera system integrates illumination and video capabilities into a portable package.
  • The camera's separation from the SPA port allows for reduced port size or the use of an additional surgical tool.
  • The system demonstrated potential for increased mobility and reduced interference between the camera and surgical instruments.

Conclusions:

  • The novel magnet camera system effectively addresses space constraints in single-port access surgery.
  • This innovation can lead to smaller port sizes and improved surgical tool manipulation.
  • Enhanced visualization and reduced instrument conflict are significant advantages for SPA procedures.