Increasing the sensitivity of an LC-MS method for screening material extracts for organic extractables via mobile
1Baxter Healthcare Corporation, Technology Resources Division, Round Lake, IL 60073, USA. Yousheng_hua@baxter.com
Abstract:
Organic extractables (substances extracted from materials used in pharmaceutical packaging) are discovered, identified, and quantified via screening of extracts with analytical methods including liquid chromatography with mass spectrometric detection (LC-MS). Because extractables include a large number of diverse compounds that are typically present in plastic extracts at low levels, the LC-MS methods must be broad scope and sensitive. To accomplish these objectives, screening studies typically couple gradient reversed-phase separations with electrospray MS detection (both positive and negative ion modes). While such methods are generally applicable for a number of extractables, they are not optimal for some commonly encountered extractables due to either poor chromatographic performance (e.g., peak tailing) or poor MS response. Modifications to mobile phase composition (e.g., pH adjustment) were examined to improve the performance of an LC-MS screening method. The use of 0.1% acetic acid with 1 mM ammonium acetate (pH 3.6) as the aqueous portion of the mobile phase provided favorable sensitivities for a number of extractables both in positive and negative ion modes. In positive ion mode, the acidic mobile phase improved responses for moderately weak basic compounds by increasing their degree of protonation. For very weak basic compounds such as amides, ammonium ions in the mobile phase promoted proton adduct responses. In negative ion mode, an acidic mobile phase containing acetate anion improved ESI responses for acidic compounds, primarily due to gas phase effects.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...