Hydrogen fluoride inhalation injury because of a fire suppression system
Dustin Zierold1, Matthew Chauviere
1David Grant USAF Medical Center, 60 MSGS/SGCQ, Travis Air Force Base, CA 94535-1800, USA.
Abstract:
Automatic fire suppression systems (FSSs) use hydrofluorocarbons (HFCs) to chemically extinguish fires. At high temperatures, HFC can release hydrogen fluoride (HF), a toxic and potentially lethal gas. We report the deaths of three U.S. military personnel at Bagram Air Base from acute respiratory failure after the FSS in their vehicle received a direct hit from a rocket-propelled grenade. Despite presenting with little to no additional signs of trauma, these individuals all died within 24 hours from HF-induced respiratory failure. When two patients later presented with similar symptoms after damage to their vehicle's FSS, they were aggressively treated with nebulized calcium and positive pressure ventilation. Both survived. The presence of HFC-containing FSSs in military vehicles may lead to future cases of HF inhalation injury, and further research must be done to help rapidly diagnose and effectively treat this injury.
More Related Videos
Related Concept Videos
Inhalational Anesthetics: Overview
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Halogens
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Acute Respiratory Failure-III