Related Experiment Video
Updated: May 24, 2026

09:06
Culture of Small Colony Variant of Pseudomonas aeruginosa and Quantitation of its Alginate
Published on: February 22, 2020
Dimensional changes in alginate impression during immersion in a disinfectant solution
Danish Muzaffar1, Syed Hammad Ahsan, Ashar Afaq
1Dental Material Sciences Department, Isra Dental College, Isra University, Hyderabad.
JPMA. the Journal of the Pakistan Medical Association
|February 24, 2012
Summary
Disinfectant immersion caused variable linear shrinkage in alginate impression materials, with thinner samples exhibiting greater dimensional instability. This suggests potential distortion in complex dental impressions.
Area of Science:
- Dental Materials Science
- Impression Techniques
- Disinfection Protocols
Background:
- Alginate impression materials are widely used in dentistry.
- Disinfection of dental impressions is crucial for infection control.
- The dimensional stability of alginates can be affected by immersion in disinfectants.
Purpose of the Study:
- To evaluate the impact of a specific disinfectant (Perform ID) on the dimensional accuracy of two alginate materials.
- To compare the shrinkage of different alginate thicknesses after disinfection.
Main Methods:
- Standardized alginate impression samples (1.5mm and 3.0mm thickness) were prepared.
- Samples were immersed in Perform ID disinfectant for one hour.
- Linear dimensional changes were measured at 5-minute intervals using a travelling microscope.
Main Results:
- Both alginate materials exhibited linear shrinkage after disinfectant immersion.
- Thinner alginate samples (1.5mm) showed significantly greater shrinkage than thicker samples (3.0mm).
- Variable shrinkage patterns were observed between the two tested alginate brands (BluePrint Cremix and Hydrogum).
Conclusions:
- Disinfectant immersion can induce variable linear shrinkage in alginate impression materials.
- Alginate thickness significantly influences dimensional stability post-disinfection.
- The findings highlight the potential for distortion in clinical dental impressions due to disinfection processes.