Related Experiment Video
Updated: May 24, 2026

Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
Assessment of asymmetry in a normal occlusion sample and asymmetric patients with three-dimensional cone beam
Je Uk Park1, Yoon-Ah Kook, Yoonji Kim
1Department of Craniomaxillofacial Surgery, Seoul St. Mary's Hospital, Medical College, The Catholic University of Korea, Seoul, South Korea.
Objective:
To characterize symmetrical features of patients with facial asymmetry and thus to find the most reliable horizontal reference lines easily used in three-dimensional images. The hypothesis was that there is a difference in the location of bilateral landmarks of the upper skull between the normal occlusion sample and skeletal Class III patients with asymmetry.
Materials And Methods:
Group 1 (normal occlusion sample) was composed of 20 Korean adults with normal occlusion and no noticeable asymmetry. Groups 2 through 4 were selected from patients who were diagnosed as skeletal Class III malocclusion and grouped according to the extent of asymmetry (group 2: symmetric mandible, no maxillary cant; group 3: asymmetric mandible, no maxillary cant; group 4: asymmetric mandible, more than 4 mm maxillary cant measured at maxillary first molars). Three-dimensional cone beam computed tomography images were taken before treatment, and bilateral landmarks of the skull were located and their vertical and horizontal differences compared.
Results:
No statistically significant difference was noted in the position of bilateral landmarks between groups, except for AG (P < .05). AG showed significant differences in vertical dimension (P < .001) and in horizontal dimension (P < .0001) between groups. The mean of the difference was clearly greatest at FM.
Conclusions:
The hypothesis is rejected. All groups had a similar pattern of asymmetry in the upper third of the face. Therefore, the transverse reference line of the bilateral Z or orbitale may be used even in patients with severe asymmetry of the maxilla with reference to the clinical photos.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

