Related Experiment Video
Updated: May 24, 2026

Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
Neck duplex Doppler ultrasound evaluation for assessing chronic cerebrospinal venous insufficiency in multiple
M Zaniewski1, J Kostecki, W Kuczmik
1Department of Surgery, Medical University of Silesia, District Specialist Hospital, Tychy, Poland.
Introduction:
Recent clinical studies have suggested a relationship between multiple sclerosis (MS) and the occurrence of pathological changes in the jugular, vertebral and azygous veins that result in abnormal blood outflow from the brain and the spinal cord. Together, these pathological changes have been designated chronic cerebrospinal venous insufficiency (CCSVI). The aim of the present study was to evaluate the usefulness of duplex Doppler ultrasound in the evaluation of central nervous system venous outflow disturbances in patients suffering from MS.
Methods:
We examined 181 patients with MS, diagnosed on the basis of the McDonald criteria, and 50 healthy volunteer controls. All patients underwent Doppler ultrasound examination of the internal jugular veins (IJV) and vertebral veins (VVs). The presence of outflow disturbances and morphological abnormalities were evaluated.
Results:
Pathological changes in the extracranial jugular veins were diagnosed in 148/181 MS patients (82%) and 7/50 control group volunteers (14%). The following abnormalities in the MS group were revealed: the presence of a reflux in the IJVs and/or VVs (54%), narrowing (54%), a complete block in the flow through the IJV (10%) and an abnormal postural control of the cerebral outflow route (25%). These particular pathologies were of statistical significance in the MS group compared with the control group. This study also revealed a correlation between the occurrence of inverted flow in patients in a sitting position and chronic progressive MS (P = 0.0033).
Conclusions:
The examinations undertaken indicate a possible connection between MS and CCSVI. The widely accessible and highly sensitive and specific Doppler ultrasound test may be useful for revealing, and preliminary analysis of, CCSVI pathologies.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Assessment of the Cardiovascular System II: Inspection
Head and Neck
