Validation of an analytical method for the determination of cadmium (Cd) in fish by atomic absorption spectrometry
L C S M Costa1, A P N Neto, M Q Araújo
1Laboratory of Residues and Contaminants - National Laboratory of Ministry of Agriculture, Livestock and Food Supply (LANAGRO-PA), Av. Almirante Barroso, 1234 Zip Code: 66095-000, Brazil.
Abstract:
The validation of an analytical method was carried out for the determination of cadmium (Cd) in fish. The method was based on sample digestion in a microwave oven and subsequent reading using an atomic absorption spectrometer with a graphite furnace. The factorial design of experiments was applied to assess method ruggedness using the methodology of Box et al. [Box GEP, Hunter WG, Hunter JS. 1978. Statistics for experiments: an introduction to design, data analysis and model building. New York (NY): Wiley], studying the influence of sample mass, volume and concentration of acid used for sample digestion and the volume of modifier used. To study the possible matrix effect in the determination of Cd, the standard addition method was also performed. The results were treated using the OLS method. For the normality test a homoskedastic distribution was observed for the developed method and the results were adjusted to the statistical model proposed. F-tests and Student's t-tests indicated that there was no matrix effect on the calibration curve between the concentration range 1.0-10.0 µg Cd l(-1). Parameters such as selectivity, precision, decision limit, detection capability and limit of quantification were established by the method of standard addition to blank samples. The limit of quantification was 6.8 µg kg(-1). Accuracy, which was evaluated by using a certified reference material, was 107.0%. The recovery of the spiked analyte was 93.69% for the concentration of 50 µg kg(-1). Precision was defined by the coefficient of variation observed (Horrat value), estimated in terms of repeatability and reproducibility, and the values were below the limit, which is 2.0. The validation procedure confirmed the suitability of the method.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation