Highly flexible capacitive strain gauge for continuous long-term blood pressure monitoring
1Department of Microsystems Engineering-IMTEK, University of Freiburg, Georges-Koehler-Allee 102, 79110 Freiburg, Germany. bingger@imtek.de
Abstract:
An innovative procedure for measuring blood pressure, with none of the disadvantages of current procedures, is proposed. A highly-flexible capacitive strain gauge has been designed to measure changes in the diameter of a blood vessel; such changes are indicative of blood pressure. The sensor is implanted and wrapped around an arterial blood vessel during the normal course of a surgical procedure. In vivo tests, demonstrating the feasibility of this concept, are reported, along with in vitro tests and notes on sensor design and fabrication. These continuous blood pressure monitoring sensors may be used for a continuous long-term monitoring of blood pressure and pulse. They may also be combined with a real-time nerve stimulation technique or a course of medication to create a closed-loop system for blood-pressure control.
More Related Videos
07:59A Strain Gauge Monitor (SGM) for Continuous Valve Gape Measurements in Bivalve Molluscs in Response to Laboratory Induced Diel-cycling Hypoxia and pH
Published on: August 1, 2018
05:57Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
Published on: March 17, 2023
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pressure Gauges
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: