Removal of low concentration Cr(VI) from aqueous solution by magnetic-fluids fixed bed using the high gradient magnetic separation
Related Experiment Video
Updated: May 24, 2026

Stable Aqueous Suspensions of Manganese Ferrite Clusters with Tunable Nanoscale Dimension and Composition
Published on: February 5, 2022
Qiang Wang1, Yueping Guan, Xiufeng Ren
1School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China.
Abstract:
The focus of this paper was a novel model of Cr(VI) extraction process. The original so-called "magnetic-fluids fixed bed" (MFFB), which bridged the solvent extraction and the fixed-bed extraction by the theory of the high gradient magnetic separation (HGMS), has been explained. The MFFB integrated the advantages of the two above mentioned classical extraction methods and overcame their drawbacks. The feasibility of this method was studied by extraction experiments of Cr(VI) from aqueous solution. The influences of the design of ferromagnetic steel wires in magnetic separation column, the pH value of feed solution, TBP concentration in magnetic fluids, and flow rate of aqueous solution in column were investigated. Under the optimum conditions, the proposed method obtained high extraction efficiency with continuous process.
Related Concept Videos
Coagulation
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Centrifugation
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Precipitation and Co-precipitation
Extraction: Advanced Methods