Related Experiment Video For Adenoma
Updated: May 24, 2026

Detection of a Circulating MicroRNA Custom Panel in Patients with Metastatic Colorectal Cancer
Published on: March 14, 2019
The Miss Rate for Colorectal Adenoma Determined by Quality-Adjusted, Back-to-Back Colonoscopies
Sang Bong Ahn1, Dong Soo Han, Joong Ho Bae
1Department of Internal Medicine, Hanyang University College of Medicine, Guri, Korea.
Background/Aims:
Colonoscopy is considered to be the gold standard for detecting adenomatous polyps. Polyps are missed during colonoscopic examination at a rate that varies from 6% to 27%. The adenoma miss rate affects colonoscopic surveillance intervals and procedural quality. We aimed to assess the adenoma miss rate and the variables affecting the rate using same-day, quality-adjusted, back-to-back colonoscopies.
Methods:
This prospective study was performed at a single institution and included 149 patients. Two consecutive same-day colonoscopies were performed by two experienced endoscopists. The adenoma miss rates and variables affecting the missed adenomas, including polyp characteristics and procedure times, were evaluated.
Results:
The miss rates of polyps, adenomas, and advanced adenomas were 16.8%, 17%, and 5.4%, respectively. The smaller polyps and increased number of polyps detected during the first colonoscopy were more likely to be missed. A longer insertion time during the colonoscopy was correlated with an increased adenoma detection rate.
Conclusions:
There was a significant miss rate in the detection of colonic adenomas even in quality-adjusted, back-to-back colonoscopies. The adenoma miss rate can be reduced with a sufficient observation time during colonoscopic insertion. The development of specific technological methods to reduce the adenoma miss rate is necessary.