Related Experiment Video
Updated: May 24, 2026

Neutron Crystallography Data Collection and Processing for Modelling Hydrogen Atoms in Protein Structures
Published on: December 1, 2020
Low-energy beam transport studies supporting the spallation neutron source 1-MW beam operation
B X Han1, T Kalvas, O Tarvainen
1Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA. hanb@ornl.gov
Abstract:
The H(-) injector consisting of a cesium enhanced RF-driven ion source and a 2-lens electrostatic low-energy beam transport (LEBT) system supports the spallation neutron source 1 MW beam operation with ∼38 mA beam current in the linac at 60 Hz with a pulse length of up to ∼1.0 ms. In this work, two important issues associated with the low-energy beam transport are discussed: (1) inconsistent dependence of the post-radio frequency quadrupole accelerator beam current on the ion source tilt angle and (2) high power beam losses on the LEBT electrodes under some off-nominal conditions compromising their reliability.